TM 5-5420-202-20-3
POWER PLANT WARNING LIGHT REPAIR (Sheet 2 of 2)
CLEANING AND INSPECTION:
1. Clean lens (A) with moist, lint free cloth.
2. Using steel wool, remove any corrosion from connector terminal (K) of lamp
assembly (G).
3. Inspect lens for cracks or deep scratches. Replace if any are found.
INSTALLATION:
1.
2.
3.
4.
5.
6.
Using fingers, connect electrical connector (A), to light assembly (B).
Using screwdriver, secure light assembly (B), to bracket (C), with two
screws (D) and lockwashers (E).
Insert
Using
Place
Place
lamp (F) in socket.
Press in and turn slightly right, and release to secure.
adjustable wrench, install adapter (G).
packing (H) on adapter (G), and install lens (J) finger tight.
MASTER BATTERY switch to ON and check that lamp (F) lights.
End
of Task
TA249131
10-190