TM 5-5420-202-20-3
RECEPTACLE MOUNTING PLATE AND GASKET REPLACEMENT (Sheet 1 of 2)
TOOLS:
Flat-tip screwdriver
9/16 in. socket with 1/2in. drive
Ratchet with 1/2 in. drive
5 in. extension with 1/2 in. drive
Spanner wrench
REMOVAL:
1.
2.
3.
Using socket with extension, remove seven
screws (A) and lockwashers (B) securing
mounting plate (C) and gasket (D) to
bulkhead.
Pull mounting
Using spanner
plate (C) away from bulkhead.
wrench, disconnect four connectors (E).
Go on to Sheet 2
10-272
4.
5.
6.
Using screwdriver, remove 16 screws (F) and
lockwashers (G) securing four receptacles (H)
and gaskets (J) to mounting plate (C).
Remove four receptacles (H) and gaskets (J).
Remove gasket (D) from mounting plate (C).
TA249213