TM 5-5420-202-20-3
Change 7
10-268.3
HEU SLAVE RECEPTACLE REPLACEMENT (Sheet 1 OF 2)
TOOLS:
9/16 inch
1/2
inch drive socket
1/2 inch drive ratchet
9/16 inch open and closed end wrench
7/16 inch
1/2
inch drive socket
7/16 inch open and closed end wrench
5 inch extension
SUPPLIES:
Lockwashers
PRELIMINARY PROCEDURES:
Disconnect three battery ground straps (page 10-268)
Remove slave receptacle cover (page 10-268.1)
REMOVAL:
1.
Using 9/16 inch wrench remove screw (A ) and lockwasher (B) from slave receptacle (C) and
main power wiring harness (D) (CKT
49
).
2.
Using 9/16 inch wrench remove screw (E) and lock washer (F) from slave receptacle (C) and
Ground wire (G) (CKT
50
).
3.
Holding nuts (H) with 7/16 inch wrench use 7/16 inch socket and ratchet to remove screws (J)
and lockwashers (K) from mounting plate (L).
4.
Remove slave receptacle (C) from mounting plate (L).
INSTALLATION:
1.
Install slave receptacle (C) into mounting plate (L).
2.
Insert four screws (J) thru mounting plate (L) and slave receptacle (C).
3.
Manually install new lockwashers (K) and nuts (H) ont o screws (J).
4.
Holding nuts (H) with 7/16 inch wrench use 7/16 inch socket and ratchet to tighten screws (J)
to mounting plate (L).
5.
Using 9/16 inch wrench install screw (E) and new lockwasher (F) thru ground wire ( G) (CKT
50
) into
slave receptacle (C).
6.
Using 9/16 inch wrench install screw (A) and new lockwasher (B) thru main power wiring harness (D)
(CKT
49
) into slave receptacle (C).
Go to Next Page