TM 5-5420-202-20-3
10-268.2
Change 7
HEU SLAVE RECEPTACLE GROUND STRAP REPLACEMENT
TOOLS:
9/16 in. open and closed end wrench
SUPPLIES:
Lockwashers
PRELIMINARY PROCEDURES:
Disconnect three battery ground straps (page 10-268)
Remove slave receptacle cover (page 10-268.1)
REMOVAL
1.
Using 9/16 inch wrench remove screw (A) and
new
lockwasher (B) from slave receptacle (C) and
slave receptacle ground strap (D) (CKT
50
).
2.
Using 9/16 inch wrench remove screw (E) and
new
lockwasher (F) from hull (G) and
slave receptacle ground strap (D) (CKT
49
).
INSTALLATION:
1.
Using 9/16 inch wrench install screw (E) and
new
lockwasher (F) thru slave receptacle ground strap (D)
(CKT
50
) into hull (G).
2.
Using 9/16 inch wrench install screw (A) and
new
lockwasher (P) thru slave receptacle ground strap (D)
(CKT
49
) into slave receptacle (C).
3.
Install slave receptacle cover (page 10-268.1).
4.
Connect three battery ground straps (page 10-268).
End of Task