TM-5-5420-202-20-4

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 4 OF 4

OCTOBER 1985

  TM-5-5420-202-20-4 - Page 190 of 534

TM 5-5420-202-20-4
INTERIOR RELEASE MECHANISM REPAIR (Sheet 5 of 11)
14.
Pull handle
CLEANING AND
13.
Using 3/32 inch punch and hammer,
drive spring pin (AE) out of shaft (Q).
Throw spring pin (AE) away.
(AF) off shaft (Q).
INSPECTION:
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable
To prevent personal injury, wear
protective goggles and gloves and use only in a wall-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vapors. Do not use near openn flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100° (38°C) and for Type #2 is 138° (50°C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and medical medical aid immediately.
1.
2.
3.
4.
5.
6.
7.
Using dry cleaning solvent, clean
metal parts.
Using cleaning fluid, clean switch
assembly and switch connectors.
Check metal parts for cracks.
Check levers, pins, pawl, and handle
shaft for bends or breaks.
Check brackets for bends, elongated
holes, or damaged points.
Check spring wire for nicks and grooves
at contact points.
Replace all defective parts.
ASSEMBLY:
1.
Push handle (A) onto shaft (B). Aline
spring pin hole of handle (A) with hole
of shaft (B).
2.
Using hammer, install new spring pin
(C) into handle (A) and shaft (B).
Go on to Sheet 6
TA248690
20-32


Back to Top