TM 5-5420-202-20-4
REAR DRAIN VALVE ASSEMBLY REPLACEMENT (Sheet 4 of 6)
CLEANING AND INSPECTION:
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. To prevent personal injury, wear
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vapors. Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100°F (38°C) and for Type #2 is 138°F (50°C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
1.
2.
3.
4.
Using drycleaning solvent and clean rags, clean all parts.
Inspect removed parts for cracks, nicks, burrs, or other defects. Replace defective parts.
Measure length of spring (A). If spring (A)
measures less than 2-1/2 inches, replace
spring (A).
Inspect mating surface of valve (B) and
valve seat (C) for nicks, cracks, burrs, rust,
or other defects. If defects are found,
replace defective part.
Go
on to Sheet
5
17-50