TM-5-5420-228-24

LAUNCHER HYDRAULICS SYSTEM M48A5/M60A1 TANK CHASSIS, TRANSPORTING: FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT; MAINTENANCE MANUAL

AUGUST 1985

  TM-5-5420-228-24 - Page 93 of 750

TM 5-5420-228-24
2-58.2
Change 3
STE/ICE Test Procedures - Continued
When performing the OFFSET test,
make sure system to be tested, is not
pressurized.
If not pressurized, you will
get an improper reading.
NOTE
First Technician (Operator’s Station)
Dial TEST SELECT switches to 51.
Press and hold TEST button until VTM display
indicates CAL.
Release TEST button.
Check that OFFSET measurement on VTM
display indicates between -1500 to +1500.
Perform OFFSET FAULT
ISOLATION (TM 9-4910-571-12 &P)
3
NO
YES
Does VTM display indicate between -1500 to
+1500?
First Technician (Operator’s Station)
The next step to be performed depends on which
dual counterbalance valve is being tested.
FOR DUAL
GO TO STEP
COUNTERBALANCE VALVE
OVERHEAD T1
5
TONGUE T1
8
TONGUE T2
11
S
C
I
S
S
O
R
S
T
1
1
4
OVERHEAD T2
17
4


Back to Top