TM-9-1200-215-34-P

AUTOMATIC FIRE CONTROL SYSTEM (AFCS)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

FEBRUARY 1999

  TM-9-1200-215-34-P - Page 16 of 266

TM 9–1200–215–34&P
1–4
WARNING
Dry cleaning solvent, mineral spirits, and paint thinners are flammable and should not be
used near an open flame.
Fire extinguishers should be nearby when these materials are
used.
Use these cleaners only in well–ventilated areas.
Cleaners evaporate quickly and thus cause drying and/or irritation of skin or eyes.
Operators
using cleaners must wear protective gloves.
Do not allow contact with eyes.
Do not use diesel fuel oil, gasoline, or benzene for cleaning.
These solvents decompose
rubber.
(1)
Remove foreign matter from assemblies by wiping with cleaning solvent (item 12, Appendix D).
Wipe
cleaned surface with a lint–free cloth (item 13, Appendix D).
(2)
When cleaning is complete, thoroughly dry areas with low pressure compressed air.
b.
Recording.
Refer to DA PAM 738–750 to select correct form and instructions for technical inspection and the
corrective actions taken.
1–13.
SPECIAL INSTRUCTIONS FOR ADMINISTRATIVE STORAGE
a.
Instructions for placing equipment in, and for removing it from administrative storage will be provided in
accordance with AR 750–1 and paragraph 1–5.
b.
Placement of equipment in administrative storage should be for short periods of time when a shortage of
maintenance efforts exists.
Items should be in mission readiness within 24 hours or within the time factors as
determined by the directing authority.
During the storage period, appropriate maintenance records will be kept
including all applicable PMCS requirements.
AFCS and PDIU LRUs will be stored/shipped in its own
storage/shipment container.
c.
Before placing equipment in administrative storage, current maintenance services and Equipment
Serviceable Criteria (ESC) evaluations should be completed, shortcomings and deficiencies corrected, and all
Modification Work Orders (MWOs) applied.
d.
Storage site selection.
Inside storage is preferred for items selected for administrative storage.
If inside
storage is not available, trucks, vans, CONEX containers and other containers may be used.
1–14.
LIST OF ACRONYMS
ACU
AFCS Computer Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADC
Analog to Digital Converter
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AFCS
Automatic Fire Control System
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BC
Ballistic Computation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BCS
Battery Computer System
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BIT
Built–In Test
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BSTF
Base Shop Test Facility
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CARC
Chemical Agent Resistant Coating
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
CCA
Circuit Card Assembly
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CEE
Commercial Equivalent Equipment
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COEI
Components of End Item
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CP
Communication Processing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CPC
Corrosion Prevention and Control
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CPU
Central Processing Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CTA
Common Table of Allowance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CTS
Contact Test Set
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DAC
Digital to Analog Converter
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DOD
Department of Defense
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Change 1