TM-9-2320-209-20-3-2

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 3 OF 3; PART 2 OF 4

MAY 1981

  TM-9-2320-209-20-3-2 - Page 322 of 552

TM 9-2320-209-20-3- 2
1 .
2 .
3 .
4 .
WARNIN G
Dry cleaning solvent is flammable. Do not use near a n
open flame .
Keep a fire extinguisher nearby whe n
solvent is used .
Use only in well-ventilated places .
Failure to do this may result in injury to personne l
and damage to equipment .
Clean hub (1) with solvent and let it dry .
Check that hub (1) is not cracked .
If hub is cracked, throw it away and ge t
a new one .
Check that inner and outer wheel bearing cups (2) are tight inside hub (1) .
If cups are loose , remove inner and outer wheel bearing cups (refer to par a
14-7) and throw away hub and get a new one .
Check that adapter (3) is not cracked or warped. If adapter is damaged ,
throw it away and get a new one .
END OF TAS K
14-2 3