(2) Blower assembly.
FRAME 1
1.
2.
3.
4.
5.
6.
7.
Unscrew and take out seven screws (1) and speed nuts (2). Life off blower
cover (3).
Loosen setscrew (4) in hub of blower wheel (5). Lift off blower wheel (5).
Carefully pull blower motor electrical lead (6) through grommeted hole in
blower plate (7).
Unscrew and take out three screws (8). Lift
three spacers (9) from blower motor (10).
Do not dip blower
damaged. Do not
be repaired.
CAUTION
motor in solvent.
take blower motor
off blower plate (7). Take off
Bearings will be
apart. It cannot
Wipe blower motor (10) clean with cloth. Inspect blower motor for broken
housing, bent shaft or signs of overheating. Inspect electrical lead (6) for
broken or worn insulation.
Get new motor if any of the conditions in step 5 are found. Get new motor if
motor was known not to be working or heavy carbon was found on igniter or
burner.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when sol-
vent is used. Use only in well-ventilated places. Fail-
ure to do this may result in injury to personnel and
damage to equipment.
Clean the rest of blower parts in dry cleaning solvent and wipe dry.
GO TO FRAME 2
21-31