STARTING AND ETHER STARTING SYSTEM OPERATION - Continued
A. PROTECTIVE CONTROL BOX
- Prevents reengagement of starter motor once engine is running.
B. BATTERIES
- Provide 24-volt electrical current for energizing electrical circuits.
C. STARTER SOLENOID
- Relays 24-volt battery power to energize starter motor.
D. STARTER MOTOR
- When energized, converts electrical energy to mechanical power as it engages
flywheel to crank engine.
E. ETHER START CYLINDER
- Stores ether used for cold-weather starting.
A
B
C
D
E
G0014DAA
Figure 2.
Starting and Ether Starting Components.