TM 9-2320-272-24-1
Table 2-3. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTlVE ACTION
Step 6.
Step 7.
Step 8.
Step 9.
Set multimeter to RX1 for continuity reading.
Disconnect battery ground cable (para. 3-126).
Connect multimeter positive lead to lead 568 and negative lead to lead 5 of alternator
terminal.
Multimeter should indicate continuity. If continuity is not indicated, there is an open
lead.
Repair broken lead 568 (para. 3-131).
END OF TESTING!
2-122