3-6. VALVE
TM 9-2320-272-24-1
6.
Install surge tank assembly (2) on exhaust manifold (9) with two screws (3). Tighten screws (3)
50-55 lb-ft (68-75 N•m).
8.
Install hoses (4), (5), (10), (12), and (12) on surge tank assembly (2) and tighen clamps (6), (11), and (13).
7.
Install surge tank assembly (2) on angle support bracket (8) with screw (1) and nut (7). Tighten
screw (1) 35-40 lb-ft (47-54 N•m).
3-28