TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cent)
Talde 2-9. Troubleshooting (Cent)
ilalfunction
Test or Inspection
Corrective Action
HEAVY-DUTY WINCH (CONT)
!. WINCH WILL NOT REWIND (M984).
Step 1. Refer to HYDRAULIC SYSTEM Troubleshooting.
If problem remains, go to Step 2.
HEAVY-DUTY WINCH
HYDRAULIC LINES
TA188044
Step
2.
Check heavy-duty winch hydraulic lines for damage.
Replace damaged hydraulic lines.
Step 3. Remove hydraulic lines from heavy-duty winch selector valve (para 19-11). Check for
blocked lines.
Clean lines.
2-185
.
.
.