Malfunction
Test or Inspection
Corrective Action
HEAVY-DUTY WINCH (CONT)
2.1. WINCH WILL NOT REWIND (M984E1).
QUICK
DISCONNECT
DISCONNECT
TA476074
Step 1. Check winch motor quick disconnects for proper connection or damage.
Fully engage quick disconnects or repair damaged quick disconnects.
Step 2. Check if crane operates (TM 9-2320-279-10).
If crane does not operate, go to MATERIAL HANDLING CRANE Troubleshooting,
MALFUNCTION 1, then return here if problem is not solved. ~
Step 3. Operate winch from manual station.
If winch will rewind, go to Step 4.
If winch will not rewind, go to Step 6.