TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-94. STARTER RELAY REMOVAL/INSTALLATION (CONT).
a. Removal.
NOTE
Tag and mark wires before
disconnecting.
(1)
Disconnect wires (1) from
starter relay (2) terminals.
(2)
Remove two screws (3),
lockwashers (4), and
nuts (5).
(3)
Remove starter relay (2).
b. Installation.
(1)
(2)
(3)
(1)
(2)
(3)
(4)
(5)
Place starter relay (2) on
engine front support.
Install two screws (3),
lockwashers (4), and
nuts (5).
Connect wires (1) to starter
relay (2) terminals.
c. Follow-on Maintenance.
Connect batteries
(para 7-91).
Install engine side panel
(TM 9-2320-279-10).
Close engine cover
(TM 9-2320-279-10).
Start engine to check
operation of relay
(TM 9-2320-279-10).
END OF TASK
Shut off engine (TM 9-2320-279-10).
7-354