TM-9-2320-280-20-2

TRUCK, UTILITY: M998 SERIES

TECHNICAL MANUAL; UNIT MAINTENANCE; VOLUME 2 OF 3

JANUARY 1996

  TM-9-2320-280-20-2 - Page 193 of 951

TM 9-2320-280-20-2
4-6.14
Change 2
4-2.2. 100/200 AMPERE ALT E R N ATOR CABLE MAINTENANCE( Co n
t ’ d )
NOTE
• Routing of the 200 amp ground cable is identical to the 100 amp
ground cable, with the exception of the 200 amp ground cable
being installed on the alternator with a washer, lockwasher, and
nut. This procedure covers the 100 amp ground cable.
• Prior to removal, tag leads for installation.
1.
Slide back rubber boot (10) and remove capscrew (6), lockwasher (7), washer (8), and ground
cable (4) from alternator (9). Discard lockwasher (7).
2.
Remove nut (1), lockwasher (2), washer (3), ground cable (4), and washer (3) from water crossover
stud (5). Discard lockwasher (2).
1.
Install washer (3), ground cable (4), washer (3), lockwasher (2), and nut (1) on water crossover
stud (5).
2.
Install ground cable (4) on alternator (9) with washer (8), lockwasher (7), and capscrew (6). Tighten
capscrew (6) to 8-12 lb-ft (11-16 N
m).
3.
Slide rubber boot (10) on capscrew (6).
f. 100/200 Ampere Alternator Ground Cable Installation
e. 100/200 Ampere Alternator Ground Cable Removal


Back to Top