TM 9-2320-280-20-2
6-18. FRONT GEARED HUB VENT LINE REPLACEMENT (Cont’d)
4. Position 11.5 to 12.5 inches (29.2 to 31.8 cm) of hose (1) between two existing outer clamps (2) and
secure existing clamps (2) with screws (3). Ensure center clamp (2) is positioned as shown.
5. Bend 90° bracket (14) on geared hub (7) 30° outward as shown.
NOTE
Do not close loop on clamps installed on control arms. Hose lines
should move freely through control arm clamp loops.
6. Install new clamp (13) on vent line hose (1), and control arm (8) with screw (10), washer
nut (11).
(12), and
FOLLOW-ON TASK: Install wheel (para. 8-3).
6-47