TM 9-2320-328-13&P-1
0096-3
DRAFT
0096
Change 1
.
HWT0609
.
Step 5.
Put cab PUMP PTO switch to off position (WP 0004).
Shut off engine
(TM 9-2320-422-10).
Disconnect main wire harness PUMP PTO pressure switch
connector.
With a test lead set, check for 22 to 28 VDC between main wire harness
wire 2700 (red) at PUMP PTO pressure switch connector, terminal A and a known good
ground.
.
If 22 to 28 VDC are not present, go to Step 8.
.
Step 6.
Pull battery disconnect switch to off position (WP 0007).
Disconnect cab instrument
panel wire harness PUMP PTO ENGAGED indicator wire 1677 (white).
With a test lead
set, check for continuity across wire 1677 (white) from main wire harness PUMP PTO
pressure switch connector, terminal B to cab instrument panel wire harness PUMP PTO
ENGAGED indicator wire 1677 connector.
.
If there is continuity, replace PUMP PTO pressure switch (WP 0155).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION