TM 9-2320-328-13&P-1
0017-8
DRAFT
0017
(14)
Mode Selection.
The mode button allows the user to toggle between pressure mode and
manual mode.
In pressure mode, the controller ECU receives feedback from the intake and
discharge transducers and adjusts the pump displacement solenoid to match the desired
pressure inputted by the user. In manual mode, the controller ECU adjusts the pump
displacement solenoid with feedback from the system only when available.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
VENDOR ART
Figure 6.
The Home Screen Once the Mode Button Is Pushed To Go Into Pressure Mode.
VENDOR ART
Figure 7.
The Home Screen Once the User Presses the OK Button Within 3 Seconds
To Go To Pressure Mode.
OK TO GO TO
PRESSURE MODE?
IDLE
ENGINE RPM
PRESET:
XXXPSI
ENGINE TEMP
PUMP INTAKE
MODE:
PRESSURE
ENGINE OIL PSI
OK TO PUMP AND
ROLL
DEC
PUMP ENGAGED
VOLT
INC
FUEL
LEVEL
PUMP DISCHARGE
PRESET:
XXXPSI
ENGINE RPM
PUMP ENGAGED
PUMP DISCHARGE
FUEL
LEVEL
IDLE
HYDRAULIC OIL
TEMP
INC
VOLT
DEC
OK TO PUMP AND
ROLL
ENGINE OIL PSI
MODE:
PRESSURE
PUMP INTAKE
ENGINE TEMP