6.
FOAM SYSTEM switch (1) is in off position.
Indicator light (2) will be out.
END OF TASK
INSTRUMENT PANEL - STANDBY MODE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Be sure to wear proper eye protection to prevent injury or death.
Open and close all
valves slowly during any procedure.
Sudden changes in pressure may cause
equipment to react faster than personnel can be alerted.
Ensure surrounding
personnel are aware of changes being made to settings on equipment.
Failure to
comply may result in serious injury or death to personnel and damage to
equipment.
NOTE
For operation of pump, most controls and procedures will be the same whether pumping
from tank, draft, or hydrant.
Operator must ensure that:
1.
ALL water discharge valve controls are in CLOSED position.
2.
ALL water inlet valve controls are in CLOSED position.
3.
ALL drains are in CLOSED position.
4.
ALL foam controls are in CLOSED/OFF position.
5.
ALL inlet and outlet ports capped.