TM 9-2320-328-13&P-1
0022-1
DRAFT
0022
Change 1
OPERATOR MAINTENANCE
FOAM AGENT FILLING/DRAINING/FLUSHING
FILLING FOAM AGENT TANK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CAUTION
•
Do not mix different types or manufacturers’ brands of foam agent in foam cell or
piping.
Mixing of different foam agents (either type or manufacturer) may cause
deterioration of foam agent, improper proportioning, and poor performance in a fire
situation.
Mixing of Class A and different types of foam agents may result in a
chemical reaction which can create globules, which can clog orifices and cause
system failure.
•
Do not spill foam agent on pressure/vacuum vents.
Clean any spilled foam agent
before continuing with procedures.
If vents become blocked, pressure could build
up in tanks and may cause damage to equipment.
1.
Vehicle should be parked on a level surface.
2.
Ensure all water and other contaminants have been drained from foam tank (1) before filling.
3.
Ensure FOAM SYSTEM DRAIN valve (2) is in CLOSED position.
4.
Unstow right rear access ladder (WP 0012).
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3125