0020
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
9.
Put PUMP PTO switch (7) to on position.
Indicator light (8) will illuminate.
10. Put HIGH IDLE switch (9) to ON position.
Indicator light (10) will illuminate.
11. Push NO. 1 DRIVER SIDE DISCHARGE valve control OPEN button (11) until green indicator light (12)
illuminates.
12. Set pressure governor to desired pressure setting (WP 0017).
13. Complete mission.
HWT0546A
.
.
.
.
.
.
.
.
.
CAUTION
Engine must be at idle before engaging PTO.
Failure to comply will result in
damage to PTO and/or transmission.