TM 9-2320-328-13&P-1
0020-1
DRAFT
0020
Change 1
OPERATOR MAINTENANCE
PUMPING FROM HYDRANT OR IN RELAY (POSITIVE WATER SOURCES)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
When backing up vehicle, one crew member must be in back of vehicle operating
rear step buzzer to communicate with operator.
Failure to comply may result in
injury or death to personnel and/or damage to equipment.
1.
Position vehicle as close to water source as possible.
2.
Park vehicle (TM 9-2320-422-10).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Do not use hard suction hose.
Hard suction hose will not hold pressure.
Hose may
fail and separate causing injury to personnel and/or damage to equipment.
NOTE
DRIVER SIDE AUX. INLET and PASSENGER SIDE AUX. INLET operate the same way.
DRIVER SIDE AUX. INLET shown.
3.
Remove cap (1) from DRIVER SIDE AUX. INLET (2).
4.
Connect 3 in. (7.6 cm) supply hose between DRIVER SIDE AUX. INLET (2) and positive water source.
WARNING
ICON 11
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3120
WARNING
ICON 72