TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 173 of 1318

TM 9-2320-328-13&P-1
0019-1
DRAFT
0019
Change 1
OPERATOR MAINTENANCE
PUMPING FROM ONBOARD WATER TANK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
When backing up vehicle, one crew member must be in back of vehicle operating
rear step buzzer to communicate with operator.
Failure to comply may result in
injury or death to personnel and/or damage to equipment.
1.
Position vehicle for convenient discharge hose layout, and bring vehicle to complete stop.
2.
Park vehicle (TM 9-2320-422-10).
NOTE
NO. 1 DRIVER SIDE DISCHARGE and NO. 2 PASSENGER SIDE DISCHARGE operate
the same way.
NO. 1 DRIVER SIDE DISCHARGE shown.
3.
Remove cap (1) from NO. 1 DRIVER SIDE DISCHARGE (2).
4.
Connect discharge hose to NO. 1 DRIVER SIDE DISCHARGE (2).
5.
Put TANK TO PUMP switch (3) to on position.
Indicator light (4) will illuminate.
6.
Prime water pump (WP 0016).
WARNING
ICON 11
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3121


Back to Top