TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 178 of 1318

TM 9-2320-328-13&P-1
0020-2
DRAFT
0020
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Valve is completely open when green indicator light illuminates.
NO.1 DRIVER SIDE DISCHARGE and NO. 2 PASSENGER SIDE DISCHARGE operate
the same way.
NO. 1 DRIVER SIDE DISCHARGE shown.
5.
Remove cap (3) from NO. 1 DRIVER SIDE DISCHARGE (4).
6.
Connect soft discharge hose to NO. 1 DRIVER SIDE DISCHARGE (4).
7.
Push DRIVER SIDE AUX. INLET valve control OPEN button (5) until green indicator light (6) illuminates.
8.
Open valve on positive water source.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT0545


Back to Top