TM 9-2320-328-13&P-1
0033-11
DRAFT
0033
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
•
Valve is completely open when green indicator light illuminates.
•
Valve is completely closed when red indicator light illuminates.
•
Do not open PUMP DRAIN valve.
43. Remove cap (31) from NO. 1 DRIVER SIDE DISCHARGE (32).
44. Put PUMP COOLER switch (9) to CLOSED position.
Indicator light (10) will go out.
45. Let pressure build above 50 psi (345 kPa).
Push NO. 1 DRIVER SIDE DISCHARGE valve control OPEN
button (33) until green indicator light (34) illuminates.
46. Let pressure drop to 0 psi (0 kPa).
Push NO. 1 DRIVER SIDE DISCHARGE valve control CLOSE button (35)
until red indicator light (36) illuminates.
47. Repeat Steps (45) and (46).
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3137