NOTE
Water tank level must be below 1/2 or empty for this Step.
Step 3.
Put DIRECT TANK FILL switch to OFF position (WP 0004).
Pull battery disconnect
switch to off position (WP 0007).
Remove relay P1 (WP 0263).
Push battery
disconnect switch to on position (WP 0007).
With a test lead set, check for continuity
across wire 2330 (blue) from relay P1 connector, terminal 2 to a known good ground.
If there is no continuity, go to Step 13.