TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 863 of 1318

TM 9-2320-328-13&P-1
0076-25
DRAFT
0076
HWT1746
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 36.
Connect air lines at tank-to-pump valve.
Disconnect pump house wire harness tank-to-
pump control valve connector.
Put cab or pump operator’s panel TANK TO PUMP
switch to open position (WP 0004) and release.
With a test lead set, check for 22 to 28
VDC between wire 2855 (red) at pump house wire harness tank-to-pump control valve
connector, terminal 1 and a known good ground.
If 22 to 28 VDC are not present, repair wire 2855 in pump house wire
harness if repairable (TM 9-2320-325-14&P), or replace pump house wire
harness.
Step 37.
Pull battery disconnect switch to off position (WP 0007).
With a test lead set, check for
continuity across wire 2200 (black) from pump house wire harness tank-to-pump control
valve connector, terminal 2 to a known good ground.
a.
If there is continuity, replace tank-to-pump control valve (WP 0271).
b.
If there is no continuity, repair wire 2200 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top