TM 9-2320-328-13&P-1
0076-24
DRAFT
0076
HWT1173
WARNING
ICON 26,66
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
NOTE
Air pressure is checked by disconnecting air lines at tank-to-pump valve and observing air
pressure escaping from air line, when tank-to-pump control valve is activated.
Air will
escape from blue air line when TANK TO PUMP switch is put to open position, and escape
from red air line when TANK TO PUMP switch is put to closed position.
System air
pressure may drop below 85 psi (586 kPa) during this procedure.
Step 35.
Disconnect air lines at tank-to-pump valve.
While an assistant puts cab or pump
operator’s panel TANK TO PUMP switch to open and close positions (WP 0004), check
if air pressure is present at tank-to-pump valve.
a.
If there is air pressure, replace tank-to-pump valve (WP 0322).
b.
If there is no air pressure, replace tank-to-pump control
valve (WP 0271).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION