TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 870 of 1318

TM 9-2320-328-13&P-1
0077-4
DRAFT
0077
HWT0633
WARNING
ICON 26,66
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
NOTE
Air pressure is checked by disconnecting air lines at under truck nozzles valve and
observing air pressure escaping from air lines, when under truck nozzles control valve is
activated.
Air will escape from blue air line when UNDER TRUCK NOZZLES switch is put
to on position, and escape from red air line when UNDER TRUCK NOZZLES switch is put
to off position.
System air pressure may drop below 85 psi (586 kPa) during this
procedure.
Step 6.
Put UNDER TRUCK NOZZLES switch to off position (WP 0004).
Put FOAM SYSTEM
switch to off position (WP 0004).
Disconnect air lines at under truck nozzles valve.
While an assistant puts UNDER TRUCK NOZZLES switch to on and off position
(WP 0004), check if air pressure is present at under truck nozzles valve.
If air pressure is present, replace under truck nozzles valve (WP 0323).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top