Step 15.
Install circuit breaker 11 (WP 0242).
Disconnect cab power distribution wire harness
cab pump control wire harness connector.
With a test lead set, check for continuity
across cab pump control wire harness wire 2854 (red) from cab pump control wire
harness UNDER TRUCK NOZZLES switch connector, terminal 5 to cab pump control
wire harness connector, terminal A.
a.
If there is continuity, repair wire 2854 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0280).
b.
If there is no continuity, repair wire 2854 in cab pump control wire
harness if repairable (TM 9-2320-325-14&P), or replace cab pump
control wire harness (WP 0281).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION