TM 9-2320-328-13&P-1
0085-16
DRAFT
0085
HWT2876
Step 20.
Connect cab pump control wire harness WINDSHIELD DELUGE switch connector.
Disconnect pump house wire harness pump house power distribution wire harness
connector DP2.
Push battery disconnect switch to on position (WP 0007).
Put
WINSHIELD DELUGE switch to on position (WP 0004).
With a test lead set, check for
22 to 28 VDC between pump house power distribution wire harness wire 2769 (red)
from pump house power distribution wire harness connector DP2, terminal A to a
known good ground.
If 22 to 28 VDC are present, repair wire 2769 in pump house power
distribution wire harness if repairable (TM 9-2320-325-14&P), or replace
pump house power distribution wire harness and block (WP 0299).