TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1041 of 1390

TM 9-2320-328-13&P-2
0281-1
DRAFT
0281
FIELD LEVEL MAINTENANCE
CAB PUMP CONTROL WIRE HARNESS REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Note routing of cab pump control wire harness prior to removal to ensure proper
installation.
Note position and remove cable ties, split loom, and cushion clips as required.
1.
Remove nut (1), lockwasher (2), wire 1027 (3), wire 1640 (4), and wire 1023 (5) from cab ground terminal
block (6).
Discard lockwasher.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2824
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Tags, Identification (WP 0400, Item 23)
Ties, Cable, Plastic (WP 0400, Item 26)
Lockwasher (1)
References
WP 0391, Fig. 57
Equipment Conditions
Cab instrument panel assembly removed