60. Install wire 4053 (7) on WATER TANK DRAIN switch (4) with lockwasher (6) and screw (5).
61. Install wire 2834 (3) on WATER TANK DRAIN switch (4) with lockwasher (2) and screw (1).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
62. Apply sealing compound to all switches and indicators that have exposed terminals.
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump operator’s panel (WP 0207)
END OF TASK
END OF WORK PACKAGE
HWT2063B
WARNING
ICON 30, 44, 27