MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1251 of 1390

TM 9-2320-328-13&P-2
0305-3
DRAFT
0305
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove two screws (12) and waterproof splice box (4) from bracket (13).
5.
Remove two fittings (8) from waterproof splice box (4).
END OF TASK
INSTALLATION
1.
Install two fittings (8) on waterproof splice box (4).
2.
Install waterproof splice box (4) on bracket (13) with two screws (12).
3.
Install two rubber compression grommets (7), plastic backers (6), and strain relief’s (5) on fittings (8).
4.
Repair yellow wire (11), black wire (10), and green wire (9) (TM 9-2320-325-14&P)