TM 9-2320-328-13&P-2
0305.1-1
DRAFT
0305.1
Change 1
FIELD LEVEL MAINTENANCE
HYDRAULIC OVERRIDE MANIFOLD SOLENOID AND PROPORTIONING VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
1.
Disconnect pump house wire harness connector (1) from solenoid connector (2).
NOTE
•
Nut holding solenoid on proportioning valve can only be installed with indexing ring facing
proportioning valve.
Note position of nut prior to removal to ensure proper installation.
•
Note orientation of solenoid prior to removal to ensure proper installation.
2.
Remove nut (3) and solenoid (4) from proportioning valve (5).
Discard solenoid.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT3491
Tools and Special Tools
Drain Pan (WP 0398, Item 4)
Standard Automotive Tool Set (SATS),
(WP 0398, Item 15)
• Wrench, Torque, Dial, 3/8” Drive, 300 in-lb
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Fluid, Hydraulic (WP 0400, Item 17)
Proportioning Valve (Includes Preformed
Packings and Solenoid) (1)
References
WP 0391, Fig. 39
Equipment Conditions
Pump house access door opened (WP 0009)
Hydraulic reservoir drained (WP 0145)
Batteries disconnected (TM 9-2320-325-14&P)