TM 9-2320-328-13&P-2
0306-1
DRAFT
0306
FIELD LEVEL MAINTENANCE
PUMP HOUSE HEATER TEST SWITCH REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
•
Tag and mark wires prior to removal to ensure proper installation.
•
Remove cable ties as required.
1.
Remove two screws (1), black wire (2), and red wire (3) from pump house heater test switch (4).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2570
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Tags, Identification (WP 0400, Item 23)
Ties, Cable, Plastic (WP 0400, Item 26)
References
WP 0391, Fig. 63
Equipment Conditions
Pump house panel E removed (WP 0339)
Pump house access door assembly opened
(WP 0009)