TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1261 of 1390

TM 9-2320-328-13&P-2
0306-1
DRAFT
0306
FIELD LEVEL MAINTENANCE
PUMP HOUSE HEATER TEST SWITCH REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Remove cable ties as required.
1.
Remove two screws (1), black wire (2), and red wire (3) from pump house heater test switch (4).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2570
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Tags, Identification (WP 0400, Item 23)
Ties, Cable, Plastic (WP 0400, Item 26)
References
WP 0391, Fig. 63
Equipment Conditions
Pump house panel E removed (WP 0339)
Pump house access door assembly opened
(WP 0009)


Back to Top