TM 9-2320-328-13&P-2
0307-4
DRAFT
0307
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Note location of switch prior to removal to ensure proper installation.
10. Remove pump house heater test switch (24) from heater diagnostic switch box (6) (WP 0306).
NOTE
Note routing of wires prior to removal to ensure proper installation.
11. Remove wire 4088 (8), wire 4086 (9), wire 4087 (21), and wire 2852 (2) from heater diagnostic switch box (6).
12. Remove two nuts (25), lockwashers (26), four washers (27) two screws (28) and heater diagnostic switch
box (6) from pump house frame (29).
Discard lockwashers.
END OF TASK
INSTALLATION
NOTE
Perform Steps (1) through (5) if heater diagnostic switch box was removed.
1.
Install heater diagnostic switch box (6) on pump house frame (29) with two screws (28), four washers (27),
two lockwashers (26) and nuts (25).
NOTE
Route wires as noted prior to removal.
2.
Route wire 2852 (2), wire 4087 (21), wire 4086 (9), and wire 4088 (3) in heater diagnostic switch box (6).
NOTE
Install switch in same position as noted.
3.
Install pump house heater test switch (24) on heater diagnostic switch box (6) (WP 0306).
HWT1736