TM 9-2320-328-13&P-2
0307-7/(8 blank)
DRAFT
0307
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12. Install wire 4088 (3) and two wires 2852 (2) on heater diagnostic switch (4) with two screws (1).
FOLLOW-ON MAINTENANCE
1.
Install pump house panel E (WP 0339)
2.
Close pump house access door assembly (WP 0008)
3.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE