TM 9-2320-328-13&P-2
0315-3
DRAFT
0315
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.
Remove pipe (9) from adapter (13).
7.
Remove four screws (14) and adapter (13) from valve (12).
8.
Remove four screws (15) and adapter (16) from valve (12).
NOTE
Note position of elbows and fittings prior to removal to ensure proper installation.
9.
Remove tee (17) and nipple (18) from adapter (13).
10. Remove nipple (18) and two fittings (4) and (19) from tee (17).
END OF TASK