0314
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
9.
Remove pipe (11) from adapter (22).
10. Remove four screws (23) and adapter (22) from valve (21).
11. Remove four screws (24) and adapter (25) from valve (21).
NOTE
Note position of fittings prior to removal to ensure proper installation.
12. Remove tee (26) and nipple (27) from adapter (22).
13. Remove nipple (27) and two fittings (4) and (28) from tee (26).
END OF TASK
INSTALLATION
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
NOTE
Install cable ties as required.
Install fittings as noted prior to removal.
1.
Apply sealing compound to threads of nipple (27) and two fittings (28) and (4).
HWT0149
WARNING
ICON 30, 44, 27