TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1286 of 1390

TM 9-2320-328-13&P-2
0311-2
DRAFT
0311
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove three screws (7), lockwashers (8), washers (9), and guard (10) from water tank cradle (11).
Discard
lockwashers.
NOTE
Remove cable ties as required.
5.
Disconnect direct tank fill valve connector (12) from direct tank fill valve wire harness connector (13).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
aa
NOTE
Note position of gaskets prior to removal to ensure proper installation.
Note orientation of valve prior to removal to ensure proper installation.
6.
With the aid of an assistant, remove eight screws (14), lockwashers (15), washers (16), gasket (17),
valve (18), gasket (19), spacer (20), and gasket (21) from flange (22) and water tank (23).
Discard
lockwashers and gaskets.
END OF TASK
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3522
HWT2174A


Back to Top