TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1292 of 1390

TM 9-2320-328-13&P-2
0313-2
DRAFT
0313
INSTALLATION
NOTE
Sealing surface must be clean prior to installing gasket.
Inspect gasket for damage. If damaged, replace gasket.
1.
Apply light coat of grease to inside of gasket (6) and two coupling halves (3).
2.
Install gasket (6) on elbow (4).
NOTE
Gasket is properly positioned when half of the gasket is on elbow and the other half of the
gasket is on pipe.
3.
Position pipe (5) against elbow (4), and install gasket (6) on pipe (5).
NOTE
Tighten screws equally on each side of clamp.
4.
Install two coupling halves (3) on elbow (4) and pipe (5) with two screws (2) and nuts (1).
END OF TASK
END OF WORK PACKAGE