TM 9-2320-328-13&P-2
0310-1
DRAFT
0310
FIELD LEVEL MAINTENANCE
PUMP HOUSE HEATER REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Fuel is very flammable and can explode easily.
To avoid serious injury or death,
keep fuel away from open fire and keep fire extinguisher within easy reach when
working with fuel.
Do not work on fuel system when engine is hot.
Fuel can be
ignited by hot engine.
When working with fuel, post signs that read NO SMOKING
WITHIN 50 FEET OF VEHICLE.
1.
Loosen clamp (1) and remove fuel line (2) from tube (3).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1553
WARNING
ICON 30,25
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Tags, Identification (WP 0400, Item 23)
Lockwasher (4)
Personnel Required
MOS 63B Wheeled Vehicle Mechanic (2)
References
WP 0391, Fig. 63
Equipment Conditions
Pump house panels K, G, and E removed