TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 156 of 1390

TM 9-2320-328-13&P-2
0121-4
DRAFT
0121
Change 1
.
HWT0911
.
Step 3.
PUT EMERG MASTER and F/R LOWER WARNING switches to off position
(WP 0004).
Turn Service Drive Lights Off (TM 9-2320-422-10).
Pull battery disconnect
switch to off position (WP 0007).
Remove circuit breaker FS 10 (WP 0242).
Check for
continuity across circuit breaker terminal connectors.
.
If there is no continuity, replace circuit breaker FS 10 (WP 0242).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION