TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 357 of 1390

TM 9-2320-328-13&P-2
0140-1
DRAFT
0140
FIELD LEVEL MAINTENANCE
HYDRAULIC OIL FILTER REPLACEMENT
INITIAL SETUP:
REMOVAL
1.
Position drain pan under filter housing (1).
2.
Remove filter housing (1) from manifold (2).
3.
Remove filter (3) and preformed packing (4) from filter housing (1). Discard preformed packing.
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1422
Tools and Special Tools
Drain Pan (WP 0398, Item 4)
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Preformed Packing (1)
References
WP 0391, Fig. 46
Equipment Conditions
Hydraulic reservoir drained (WP 0145)
Pump house panel H removed (WP 0339)


Back to Top