TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 360 of 1390

TM 9-2320-328-13&P-2
0141-2
DRAFT
0141
REMOVAL
NOTE
Cap and plug hoses upon removal.
Tag and mark hoses prior to removal to ensure proper installation.
Place suitable drain pan under hoses.
1.
Remove hose 1682902 (1) and preformed packing (2) from elbow (3). Discard preformed packing.
2.
Remove hose 1682906 (4) and preformed packing (5) from fitting (6).
Discard preformed packing.
3.
Remove hose 1682910 (7) and preformed packing (8) from tee (9). Discard preformed packing.
HWT1805


Back to Top