TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 831 of 1390

TM 9-2320-328-13&P-2
0237.1-3
DRAFT
0237.1
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove four screws (13), lockwashers (14), washers (15), and 24-volt 15 amp per bank battery charger (16)
from bracket (17).
Discard lockwashers.
5.
Remove four nuts (18), lockwashers (19), eight washers (20), four screws (21), and bracket (17) from
bracket (22).
Discard lockwasher.
END OF TASK
INSTALLATION
NOTE
Bracket (17) must be installed on bracket (22) when installing 15 amp per bank battery
charger.
1.
Install bracket (17) on bracket (22) with four screws (21), eight washers (20), four lockwashers (19), and
nuts (18).
2.
Install 24-volt 15 amp per bank battery charger (16) on bracket (17) with four washers (15), lockwashers (14),
and screws (13).
HWT3454