14. Remove four nuts (30), lockwashers (31), eight washers (32), four screws (33), and bracket (17) from pump
house frame (34) and vehicle.
Discard lockwashers.
END OF TASK
INSTALLATION
NOTE
Perform Steps (1) through (9) if bracket was removed.
1.
Install bracket (17) on pump house frame (34) with four screws (33), eight washers (32), four
lockwashers (31), and four nuts (30).
2.
Install No. 2 passenger side discharge valve (29) on bracket (17) (WP 0162).
3.
Install passenger side auxiliary inlet valve (28) on bracket (17) (WP 0159).
4.
Install pump drain valve (27) on bracket (17) (WP 0321).
5.
Install water pump blow out air line and fitting (26) on bracket (17) (WP 0384).
6.
Install water pump blow out valve (25) on bracket (17) (WP 0384).
7.
Install decals and data plates (24) on bracket (17) (WP 0326).
8.
Install foam system drain valve (23) on bracket (17) (WP 0171).
9.
Install striplight and bracket (22) on bracket (17) (WP 0215).